Auto Bipap Resmed Lumis 100 VPAP S

Resmed -Respiratory care, sleep, apnea, Auto cpap, bipap devices

 

Type/Size   
Quantity      Numbers

Price  75000

Resmed Lumis 100 VPAP S

PERSONALISED VENTILATION MADE EASY

Lumis 100 VPAP S is a noninvasive ventilator designed for spontaneously breathing, non-dependent patients with respiratory insufficiency.

The ventilator is easy to set up and use, and is supported by ResMed’s ResScan™ patient management software.

Individually Responsive With Intelligentair

IntelligentAir is a collection of ResMed technologies that can tailor therapy to individual breathing needs

FEATURES

  • Vsync provides excellent patient–ventilator synchrony, even in the presence of significant leak.
  • TiControl™ lets you set min and max limits on either side of the patient’s ideal inspiratory time to encourage spontaneous breath.
  • Trigger and cycle helps you optimise settings according to the patient’s condition, using five trigger and cycle sensitivity levels.
  • QuickNav for low-touch therapy adjustment. By simply double-clicking the home button on the device, you can toggle between the Settings and Monitoring screens to change and check settings quickly and easily.
  • Climate Control Auto for automatic humidification. When used with a HumidAir™ heated humidifier and ClimateLineAir™ heated tube, Lumis delivers humidification automatically – no settings to change and no complicated menus to navigate.
  • Ramp and Ramp Down for extra comfort. Lumis offers both Ramp and Ramp Down features to help patients ease into and out of each therapy session.
  • ResScan software for advanced clinical insights. ResScan enables you to download your patients’ therapy data, change ventilator settings, and gain insight into their therapy progress across a number of metrics (including AHI, leak and pressure). High-resolution data (at 25 Hz) is also available for breath-by-breath analysis and even greater insight.
Modes Available: CPAP, SOperating pressure2–25 cm H2 O (2–25 hPa) in S mode 4–20 cm H2 O (4–20 hPa) in CPAP modeSound pressure level26.6 dBA with uncertainty of 2 dBA as measured according to ISO 17510-1:2009 (CPAP mode)EPAP2–25 cm H2O

Operating temperature/ humidity/altitude+5°C to +35°C/ 10–95% relative humidity, non-condensing/ Sea level to 2,591 m; air pressure range 1013 hPa to 738 hPaWeight1.10 KgPower ConsumptionInput range: 100–240V, 50–60Hz, 57VA (typical power consumption) 108VA (peak power consumption)Dimensions (L x W x H)116 mm x 205 mm x 150 mm

.